Awake during General Anesthesia with BispectralIndex Value of 35

Awake during General Anesthesia with BispectralIndex Value of 35

초록

Awareness of intraoperative events in patients under general anesthesia is rare, but awareness during anesthesia is a serious complication that leads to anxiety and post-traumatic stress disorder. The Bispectral Index (BIS) has generally been accepted as a measurement of hypnosis under anesthesia. It is derived from a processed electroencephalogram and computer algorithm that assigns a numerical value based on the probability of consciousness. A 46-year-old, 65-kg male without underlying disease underwent elective surgery for ventral hernia. The patient in this case was administered an anesthetic that we frequently use and then average BIS value are 35. But he experienced awake during general anesthesia. We describe the first case of intraoperation awake under BIS 40 using desflurane.

키워드

Anesthesia; Consciousness monitors; Intraoperative complication; Mental recall
제목
Awake during General Anesthesia with BispectralIndex Value of 35
제목 (타언어)
Awake during General Anesthesia with BispectralIndex Value of 35
저자
이세진; 김순임; 옥시영; 김상호; 박선영; 김문규; 전혜림; 서혜진; 조아나; 박세광
발행일
2013
저널명
Soonchunhyang Medical Science
권
19
호
1
페이지
29 ~ 30