Correlation between Surrogate Quality Indicators for Adenoma Detection Rate and Adenoma Miss Rate in Qualified Colonoscopy, CORE Study: KASID Multicenter Study

Citations

WEB OF SCIENCE

10
Citations

SCOPUS

11

초록

Background/Aims: The adenoma detection rate (ADR) does not reflect the complete detection of every adenoma during colonoscopy; thus, many surrogate indicators have been suggested. This study investigated whether the ADR and surrogate quality indicators reflect the adenoma miss rate (AMR) when performing qualified colonoscopy. Methods: We performed a prospective, multicenter, cross-sectional study of asymptomatic examinees aged 50 to 75 years who underwent back-to-back screening colonoscopies by eight endoscopists. The ADR and surrogate quality indicators, including polyp detection rate, total number of adenomas per colonoscopy, additional adenomas found after the first adenoma per colonoscopy (ADR-Plus), and total number of adenomas per positive participant, were calculated for the prediction of AMR. Results: A total of 371 back-to-back colonoscopies were performed. There was a significant difference in ADRs (range, 44% to 75.4%; p=0.024), polyp detection rates (range, 56% to 86.9%; p=0.008) and adenomas per positive participants (range, 1.19 to 2.30; p=0.038), and a tendency of a difference in adenomas per colonoscopy (range, 0.62 to 1.31; p=0.051) and ADR-Plus (range, 0.13 to 0.70; p=0.054) among the endoscopists. The overall AMR was 20.1%, and AMRs were not different (range, 13.9 to 28.6; p>0.05) among the endoscopists. No quality indicators were significantly correlated with AMR. The number of adenomas found during the first colonoscopy was an independent factor for increased AMR (odds ratio, 1.79; p<0.001). Conclusions: The colonoscopy quality indicators were significantly different among high-ADR endoscopists, and none of the quality indicators reflected the AMR of good quality colonoscopy performances. The only factor influencing AMR was the number of adenomas detected during colonoscopy. (Gut Liver, Published online December 21, 2021)

키워드

E-mail medgun@schmc; ac; kr; Key Words; Colonoscopy; Adenoma; Miss rate; Quality indicator; COLORECTAL NEOPLASTIC POLYPS; CANCER; RISK
제목
Correlation between Surrogate Quality Indicators for Adenoma Detection Rate and Adenoma Miss Rate in Qualified Colonoscopy, CORE Study: KASID Multicenter Study
저자
Han, Jae Hee; Kim, Hyun Gun; Ahn, Eu Mi; Park, Suyeon; Jeon, Seong Ran; Cha, Jae Myung; Kwak, Min Seob; Jung, Yun ho; Shin, Jeong Eun; Shin, Hyun Deok; Cho, Young-Seok
DOI
10.5009/gnl210287
발행일
2022-09
유형
Article; Early Access
저널명
Gut and Liver
권
16
호
5
페이지