상세 보기
Evaluation of a newly modified nonflared fully covered metal stent, 12 mm in diameter, for intraductal placement in patients with malignant biliary strictures: a feasibility study
- Choi, Hyun Jong;
- Moon, Jong Ho;
- Lee, Yun Nah;
- Kim, Hyun Su;
- Choi, Moon Han;
- ... Lee, Tae Hoon;
- 외 4명
WEB OF SCIENCE
17SCOPUS
17초록
Background and study aim: The nonflared ends of fully covered, self-expandable, metal stents (FCSEMSs) may minimize stent-induced ductal injury. Suprapapillary intraductal placement of nonflared FCSEMSs for malignant biliary stricture might reduce duodenobiliary reflux and pancreatitis. The aim of this study was to evaluate the efficacy of a newly modified, nonflared FCSEMS for intraductal placement in patients with malignant biliary stricture. Patients and methods: A total of 51 patients with nonhilar, extrahepatic, malignant biliary stricture were enrolled prospectively. The nonflared FCSEMS is 12mm in diameter, and has a central saddle and a distal lasso of 7cm in length. An FCSEMS was placed above the papilla in all patients, with the central saddle positioned at the stricture to prevent stent migration. Results: The technical and clinical success rates were 100% and 98%, respectively. Early adverse events occurred in one patient (2.0 %; mild pancreatitis). A total of 12 patients underwent surgery with curative intent, one of whom (8.3 %) experienced a postoperative adverse event. No stent migration occurred in any of the patients. Cholecystitis developed in one patient (2.0 %) as a late adverse event. Stent occlusion occurred in 44.7% (17/38), and endoscopic removal of the stent was successful in 87.5% of patients. The mean stent patency was 297 days (95% confidence interval, 211-383). Conclusions: Intraductal placement of the non-flared FCSEMS, 12mm in diameter, was feasible for the palliative and preoperative management of patients with malignant biliary stricture. Longterm follow-up and prospective comparative studies are needed to evaluate the usefulness of intraductal placement of this stent.
키워드
- 제목
- Evaluation of a newly modified nonflared fully covered metal stent, 12 mm in diameter, for intraductal placement in patients with malignant biliary strictures: a feasibility study
- 저자
- Choi, Hyun Jong; Moon, Jong Ho; Lee, Yun Nah; Kim, Hyun Su; Choi, Moon Han; Lee, Tae Hoon; Cha, Sang-Woo; Cho, Young Deok; Park, Sang-Heum; Kim, Sun-Joo
- 발행일
- 2016-07
- 유형
- Article
- 저널명
- Endoscopy
- 권
- 48
- 호
- 7
- 페이지
- 625 ~ 631
- 언어
- ENG
- 출판사
- Georg Thieme Verlag
- 발행국가
- 독일
- 분량
- 7 페이지
- ISSN
- E 1438-8812
P 0013-726X