Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning
  • Ku, Hee Kwon
  • Boo, Hyunjin
  • Song, Geun-Dong
  • Lee, Deokhee
  • Yoo, Kaphyun
  • ... Park, Byung Gi
Citations

WEB OF SCIENCE

13
Citations

SCOPUS

16

초록

The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a highresolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 mm were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 mm airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 mm of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants. (c) 2023 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

키워드

HEPA filterAerosol removal efficiencyPlasma arc cuttingRadioactive aerosolNuclear power plant decommissioningMEDIAEFFICIENCYSIZE
제목
Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning
제목 (타언어)
Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning
저자
Ku, Hee KwonBoo, HyunjinSong, Geun-DongLee, DeokheeYoo, KaphyunPark, Byung Gi
DOI
10.1016/j.net.2023.01.016
발행일
2023-05
유형
Article
저널명
Nuclear Engineering and Technology
55
5
페이지
1830 ~ 1837