가동형 삽입물을 이용한 슬관절 전치환술 후에 발생한 폴리에틸렌 마모와 내측 활막 증식을 동반한 슬개골 덜컹 증후근의 증례보고

Patellar Clunk Syndrome with Polyethylene Wear and Medial Synovial Hypertrophy after Mobile Bearing Total Knee Arthroplasty: A Case Report

초록

Patellar clunk syndrome after total knee arthroplasty is a complication that causes pain and poping or catching of patella. We experienced a case after mobile bearing total knee arthroplasty that medial synovial tissue was impinged between patella and femoral component and intra-articular fibrotic nodule of superior pole of patella was observed. Also, wear of Polyethylene were observed at anterio side. We resolved the patient symptom after excision of fibrotic nodule, synovectomy of medial synovial hypertrophy, and change of polyethylene. We report this case with literature review.

키워드

PatellaTotal knee arthroplastyPatellar clunk syndrome
제목
가동형 삽입물을 이용한 슬관절 전치환술 후에 발생한 폴리에틸렌 마모와 내측 활막 증식을 동반한 슬개골 덜컹 증후근의 증례보고
제목 (타언어)
Patellar Clunk Syndrome with Polyethylene Wear and Medial Synovial Hypertrophy after Mobile Bearing Total Knee Arthroplasty: A Case Report
저자
임수재장문석윤준희이상혁강희경
발행일
2011
저널명
Soonchunhyang Medical Science
17
2
페이지
131 ~ 133