상세 보기
가동형 삽입물을 이용한 슬관절 전치환술 후에 발생한 폴리에틸렌 마모와 내측 활막 증식을 동반한 슬개골 덜컹 증후근의 증례보고
Patellar Clunk Syndrome with Polyethylene Wear and Medial Synovial Hypertrophy after Mobile Bearing Total Knee Arthroplasty: A Case Report
- 임수재;
- 장문석;
- 윤준희;
- 이상혁;
- 강희경
초록
Patellar clunk syndrome after total knee arthroplasty is a complication that causes pain and poping or catching of patella. We experienced a case after mobile bearing total knee arthroplasty that medial synovial tissue was impinged between patella and femoral component and intra-articular fibrotic nodule of superior pole of patella was observed. Also, wear of Polyethylene were observed at anterio side. We resolved the patient symptom after excision of fibrotic nodule, synovectomy of medial synovial hypertrophy, and change of polyethylene. We report this case with literature review.
키워드
Patella; Total knee arthroplasty; Patellar clunk syndrome
- 제목
- 가동형 삽입물을 이용한 슬관절 전치환술 후에 발생한 폴리에틸렌 마모와 내측 활막 증식을 동반한 슬개골 덜컹 증후근의 증례보고
- 제목 (타언어)
- Patellar Clunk Syndrome with Polyethylene Wear and Medial Synovial Hypertrophy after Mobile Bearing Total Knee Arthroplasty: A Case Report
- 저자
- 임수재; 장문석; 윤준희; 이상혁; 강희경
- 발행일
- 2011
- 저널명
- Soonchunhyang Medical Science
- 권
- 17
- 호
- 2
- 페이지
- 131 ~ 133
- 언어
- KOR
- 출판사
- 순천향의학연구소
- 발행국가
- 대한민국
- 분량
- 3 페이지
- ISSN
- P 2233-4289