상세 보기
Iris-fixated phakic intraocular lens implantation in an adult with retinopathy of prematurity: 1-year follow-up
- Kim, Young Shin;
- Chung, Jin Kwon;
- Lee, Sung Jin
WEB OF SCIENCE
0SCOPUS
0초록
To report a case of iris-fixated phakic intraocular lens (pIOL) implantation in a patient with an extremely steep cornea, shallow anterior chamber, and small corneal diameter caused by retinopathy of prematurity (ROP) and scleral encircling. Case report. Iris-fixated pIOLs were implanted in a 19-year-old patient with refraction of -18.5 -0.75 x 180 in the right eye and -15.5 -1.25 x 180 in the left eye. The keratometric values were 53.50 and 51.25 diopters (D) in the right eye and 54.75 and 51.75 D in the left eye. The white-to-white diameter and anterior chamber depth were 10.6 and 3.37 mm, respectively, in the right eye and 10.5 and 3.33 mm, respectively, in the left eye. A small pIOL was used to guarantee a safety distance and resulted in a one-line gain in uncorrected distant visual acuity and stable endothelial cell density 1 year after surgery. An iris-fixated pIOL Vis therefore an effective option for myopic patients with ROP.
키워드
- 제목
- Iris-fixated phakic intraocular lens implantation in an adult with retinopathy of prematurity: 1-year follow-up
- 저자
- Kim, Young Shin; Chung, Jin Kwon; Lee, Sung Jin
- 발행일
- 2018-06
- 유형
- Editorial Material
- 권
- 38
- 호
- 3
- 페이지
- 1333 ~ 1337
- 언어
- ENG
- 출판사
- Kluwer Academic Publishers
- 발행국가
- 네덜란드
- 분량
- 5 페이지
- ISSN
- E 1573-2630
P 0165-5701