Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan
  • Heo, Yeong-Cheol
  • Cho, Jae-Hwan
  • Lee, Hyun-Jeong
  • Lee, Hae-Kag
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was 2.51 +/- 0.12 mm with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.

키워드

TOF angiographyfluid velocitylength of inner cavitysignal-to-noise ratiocontrast-to-noise ratioMAXIMUM-INTENSITY-PROJECTIONINTRACRANIAL VASCULAR STENOSISMR-ANGIOGRAPHYCOMPUTED-TOMOGRAPHYOCCLUSIONDISEASE
제목
Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography
저자
Kim, Eng-ChanHeo, Yeong-CheolCho, Jae-HwanLee, Hyun-JeongLee, Hae-Kag
DOI
10.4283/JMAG.2014.19.2.185
발행일
2014-06
유형
Article
저널명
Journal of Magnetics
19
2
페이지
185 ~ 191