The influence of contralateral circulation on computational fluid dynamics of intracranial arteries: simulated <i>versus</i> measured flow velocities

Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

Background This study aimed to retrospectively evaluate the influence of contralateral anterior circulation on computational fluid dynamics (CFD) of intracranial arteries, by comparing the CFD values of flow velocities in unilateral anterior circulation with the measured values from phase-contrast magnetic resonance angiography (PC-MRA).Methods We analyzed 21 unilateral anterior circulation models without proximal stenosis from 15 patients who performed both time-of-flight MRA (TOF-MRA) and PC-MRA. CFD was performed with the inflow boundary condition of a pulsatile flow of the internal carotid artery (ICA) obtained from PC-MRA. The outflow boundary condition was given as atmospheric pressure. Simulated flow velocities of the middle cerebral artery (MCA) and anterior cerebral artery (ACA) from CFD were compared with the measured values from PC-MRA.Results The velocities of MCA were shown to be more accurately simulated on CFD than those of ACA (Spearman correlation coefficient 0.773 and 0.282, respectively). In four models with severe stenosis or occlusion of the contralateral ICA, the CFD values of ACA velocities were significantly lower (< 50%) than those measured with PC-MRA. ACA velocities were relatively accurately simulated in the models including similar diameters of both ACAs.Conclusion It may be necessary to consider the flow condition of the contralateral anterior circulation in CFD of intracranial arteries, especially in the ACA.

키워드

Carotid artery (internal)HemodynamicsIntracranial aneurysmMagnetic resonance angiographyPulsatile flowMIDDLE CEREBRAL-ARTERYNATURAL-HISTORYANEURYSMSPATTERNS
제목
The influence of contralateral circulation on computational fluid dynamics of intracranial arteries: simulated <i>versus</i> measured flow velocities
저자
Oh, SujeongSong, YunsunLim, HyunkyungKo, YoungbaePark, Sungtae
DOI
10.1186/s41747-023-00370-9
발행일
2023-09
유형
Article
저널명
European Radiology Experimental
7
1