프로토타입과 상업용 프로그램을 사용한 전산유체역학의 비교: 뇌혈관 동맥류 모델의 입구 혈관 길이에 따른 차이

Computational Fluid Dynamics: Comparison of Prototype and Commercial Solutions for Intracranial Aneurysms with Different Entrance Length

초록

Purpose: The aim of this study is to evaluate the influence of entrance length into computational fluid dynamics (CFD), for distal internal carotid artery (ICA) aneurysms. Materials and Methods: Two different solutions were used: Siemens prototype software (SW; prototype, not commercially available) and the package of commercial CFD SW (commercials). Twelve models of aneurysm at the distal ICA were obtained from three dimensional angiography. The original models had longer entrance lengths from the cervical segment of ICA, whereas intracranial (IC) model lengths were shorter from the proximal cavernous ICA. Results: The prototype showed faster flow than the commercial CFD, when comparing the maximum value on a velocity scale. Visualization of pathline within the aneurysm sac was seen well by the prototype, except one original model which showed a pathline leak. With IC models, both tools showed high correlation with the flow velocity. Conclusion: We believe that the CFD might be influenced by different solvers and entrance length of distal ICA aneurysm models.

키워드

Hemodynamics Cerebral Angiography Intracranial Aneurysm
제목
프로토타입과 상업용 프로그램을 사용한 전산유체역학의 비교: 뇌혈관 동맥류 모델의 입구 혈관 길이에 따른 차이
제목 (타언어)
Computational Fluid Dynamics: Comparison of Prototype and Commercial Solutions for Intracranial Aneurysms with Different Entrance Length
저자
박성태고영배
DOI
10.3348/jksr.2017.77.3.133
발행일
2017
저널명
대한영상의학회지
77
3
페이지
133 ~ 142