상세 보기
An augmented reality mobile application for weight estimation in paediatric patients: A prospective single-blinded cross-sectional study
- Nah, Sangun;
- Choi, Sungwoo;
- Kang, Nayeon;
- Bae, Kyung Yoon;
- Kim, Ye Rim;
- ... Han, Sangsoo;
- 외 2명
WEB OF SCIENCE
4SCOPUS
3초록
Introduction: Determining the exact weight of children is a challenging task during emergency situations. Current guidelines recommend the use of length-based weight- estimating tapes. However, healthcare providers must either always carry the tapes or take time to locate them. Moreover, they may not know how to use them. To address these issues, we developed an augmented reality smartphone application for length-based weight estimation called the Paediatric Augmented Reality Scale (PARS). We evaluated its performance and compared it to that of the Broselow tape (BT) and Paediatric Advanced Weight Prediction in the Emergency Room extra-long and extra-large (PAWPER-XL) tape methods. Method: A prospective, single-blinded cross-sectional study was conducted with children aged 1 month to 12 years who visited the emergency department of the tertiary university hospital in Bucheon, South Korea between July 2021 and February 2022. This study aimed to evaluate the measurement agreement and performance of 3 methods: BT, PAWPER-XL and PARS. Results: In all, 1090 participants were enrolled, and 639 (58.6%) were male. The mean age of the participants was 4.1 +/- 2.8 years, with a mean height of 102.7 +/- 21.7 cm and mean weight of 18.8 +/- 9.5 kg. Compared to BT and PAWPER-XL, PARS exhibited lower mean absolute percentage error (9.60%) and root mean square percentage error (3.02%). PARS achieved a higher proportion of weights estimated within 10% of the actual weight (63.21%), outperforming BT (57.25%) and PAWPER- XL ( 62.47%). The intraclass correlation coefficients for the actual and estimated weights of BT, PAWPER-XL and PARS were 0.952, 0.969 and 0.973, respectively (P<0.001). Conclusion: PARS exhibited a modestly better performance than BT and PAWPER-XL in estimating body weight. PARS- estimated body weights correlated fairly accurately with the actual body weights. PARS holds potential utility in paediatric emergencies.
키워드
- 제목
- An augmented reality mobile application for weight estimation in paediatric patients: A prospective single-blinded cross-sectional study
- 저자
- Nah, Sangun; Choi, Sungwoo; Kang, Nayeon; Bae, Kyung Yoon; Kim, Ye Rim; Kim, Minsol; Moon, Ji Eun; Han, Sangsoo
- 발행일
- 2023-12
- 유형
- Article
- 저널명
- Annals Academy of Medicine Singapore
- 권
- 52
- 호
- 12
- 페이지
- 660 ~ 668
- 언어
- ENG
- 출판사
- ACAD MEDICINE SINGAPORE
- 발행국가
- 싱가포르
- 분량
- 9 페이지
- ISSN
- E 2972-4066
P 2972-4066