Trends in the incidence rate of device-associated infections in intensive care units after the establishment of the Korean Nosocomial Infections Surveillance System

  • Choi, J. Y.
  • Kwak, Y. G.
  • Yoo, H.
  • Lee, S. -O.
  • Kim, H. B.
  • ... Kim, T. H.
  • 외 12명
Citations

WEB OF SCIENCE

28
Citations

SCOPUS

29

초록

Background: The effectiveness of continuous nationwide surveillance on healthcare-associated infections should be investigated in each country. Aim: To assess the rate of device-associated infections (DAIs) in intensive care units (ICUs) since the establishment of the Korean Nosocomial Infections Surveillance System (KONIS). Methods: Nationwide data were obtained on the incidence rate of DAI in ICUs reported to KONIS by all participating hospitals. The three major DAIs were studied: ventilator-associated pneumonia (VAP), central line-associated bloodstream infection (CABSI), and catheter-associated urinary tract infection (CAUTI). The pooled and year-wise incidence rates (cases per 1000 device-days) of these DAIs were determined for the period 2006 and 2012. In addition, data from institutions that had participated in KONIS for at least three consecutive years were analysed separately. Findings: The number of ICUs participating in KONIS gradually increased from 76 in 2006 to 162 in 2012. Between 2006 and 2012, the incidence rate per 1000 device-days for VAP decreased significantly from 3.48 to 1.64 (F = 11, P < 0.01), for CAUTI the rate decreased non-significantly from 1.85 to 1.26 (F = 2.02, P = 0.07), and for CABSI the rate also decreased non-significantly from 3.4 to 2.57 (F = 1.73, P = 0.12). In the 132 ICUs that had participated in KONIS for at least three consecutive years, the VAP rate significantly decreased from the first year to third year (F = 20.57, P < 0.01), but the rates of CAUTI (F = 1.06, P = 0.35) and CABSI (F = 1.39, P = 0.25) did not change significantly. Conclusion: The decreased incidence rate of VAP in ICUs in Korea might be associated with the continuous prospective surveillance provided by KONIS. (C) 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

키워드

Device-associated infectionsHealthcare-associated infectionSurveillanceRISK-FACTORSHOSPITALS
제목
Trends in the incidence rate of device-associated infections in intensive care units after the establishment of the Korean Nosocomial Infections Surveillance System
저자
Choi, J. Y.Kwak, Y. G.Yoo, H.Lee, S. -O.Kim, H. B.Han, S. H.Choi, H. J.Kim, Y. K.Kim, S. R.Kim, T. H.Lee, H.Chun, H. K.Kim, J. -S.Eun, B. W.Kim, D. W.Koo, H. -S.Bae, G. -R.Lee, K.
DOI
10.1016/j.jhin.2015.06.002
발행일
2015-09
유형
Article
저널명
Journal of Hospital Infection
91
1
페이지
28 ~ 34