Quality assurance for a multicenter Phase II study of stereotactic ablative radiotherapy for hepatocellular carcinoma <= 5 cm: a planning dummy run

Citations

WEB OF SCIENCE

4
Citations

SCOPUS

4

초록

Objective: The Korean Radiation Oncology Group (12-02) investigated the outcome of stereotactic ablative radiotherapy for hepatocellular carcinoma <= 5 cm using 60 Gy in three fractions. To evaluate dosimetric differences and compliance in a multicenter trial, a planning dummy run procedure was performed. Methods: All six participating institutions were provided the contours of two dummy run cases. Plans were performed following the study protocol to cover the planning target volume with a minimum of 90% of the prescription dose and to satisfy the constraints for organs at risk. We assessed the institutional variations in plans using dose-volume histograms. Results: Different planning techniques were applied: static intensity-modulated radiotherapy in two institutions, CyberKnife in two institutions and RapidArc in two institutions. The conformity index of all 12 plans was <= 1.2. In terms of the planning target volume coverage, all participants followed our study protocol. For the second dummy run case, located in Segment 8 near the heart, the minimum dose of the planning target volume (D-99%: dose covering 99% of the planning target volume) was variable because there was no mention of constraints of D-99% of the planning target volume in the study protocol. As an important organ at risk, the normal liver volumes receiving <17 Gy in all 12 plans were >700 ml. Conclusions: Dosimetric parameters showed acceptable compliance with the study protocol. However, we found the possibility of underdose to the planning target volume if the hepatocellular carcinoma lesion was located near organs at risk such as the heart. Based on this dummy run, we will conduct individual case reviews to minimize the effects of study protocol deviation.

키워드

dummy runhepatocellular carcinomamulticenter trialquality assurancestereotactic radiotherapyBODY RADIATION-THERAPYLOCAL SALVAGE TREATMENTTRIALONCOLOGYOUTCOMESCANCER
제목
Quality assurance for a multicenter Phase II study of stereotactic ablative radiotherapy for hepatocellular carcinoma <= 5 cm: a planning dummy run
저자
Bae, Sun HyunKim, Mi-SookJang, Won IlKim, Kum BaeCho, Kwang HwanKim, Woo ChulLee, Chang YeolKim, Eun SeogChoi, Chul WonChang, A. RamJo, SunmiKim, Jin-Young
DOI
10.1093/jjco/hyw156
발행일
2017-06
유형
Article
저널명
Japanese Journal of Clinical Oncology
47
6
페이지
535 ~ 542