Ultrasound-Guided Deployment of a Plug-Based Vascular Closure Device in Femoral Arteries with Calcified Plaque or Stenosis

Citations

WEB OF SCIENCE

4
Citations

SCOPUS

5

초록

From January 2019 to January 2020, 106 patients (age, 64.8 +/- 14.1 years; male, 63.2%) were included to retrospectively investigate the feasibility and safety of ultrasound-guided deployment of ExoSeal after femoral artery access. Baseline characteristics were not different except for age (P =.022), body mass index (P =.009), and diameter (P <.001) between the calcified plaque or stenosis (CS) group (n = 49) and non-CS group (n = 57). The overall technical and clinical success rates were 96.2% and 100%, respectively. The technical (CS group, 48/49; non-CS group, 54/57) and clinical success rates (100%), time to hemostasis (CS group, 3.21 +/- 0.54 min; non-CS group, 3.39 +/- 0.71 min), and complication rates (CS group, 1/49; non-CS group, 0/57) were not different between the 2 groups. ExoSeal seems to be safe to use under ultrasound guidance in the femoral arteries with CS.

키워드

MANUAL COMPRESSIONPUNCTUREACCESSSAFETY
제목
Ultrasound-Guided Deployment of a Plug-Based Vascular Closure Device in Femoral Arteries with Calcified Plaque or Stenosis
저자
Lee, Hyoung NamHyun, DonghoLee, Woong HeeKim, Seung SooBae, Suk HyunHwang, Jeong AhKo, Seong Eun
DOI
10.1016/j.jvir.2021.02.017
발행일
2021-06
유형
Article
저널명
Journal of Vascular and Interventional Radiology
32
6
페이지
802 ~ 806